null

SSC Accepts Returns and Refunds only on Manufacturing Defects - Please call our Service Center for Additional Details 

Alcohol Screening Device - A6000 Standard | Dräger

(No reviews yet) Write a Review
SKU:
3706961
UPC:
4026056130375
$1,953.72
Frequently bought together:

Description

Alcohol Screening Device - A6000 Standard | Dräger

Dräger Alcotest 6000
The Dräger Alcotest® 6000 allows the professional user to perform a breath alcohol test with speed and precision. The measuring technology of this small and user-friendly portable measuring device has already been proven worldwide and has been sold over 1,000,000 times.

Breath alcohol testing made easy
The device is ready to use within seconds. This means that you can perform an (active) test on a subject at any time. It is also possible to measure alcohol in the ambient air (passive), in which case a mouthpiece isn‘t required.
All functions required for a measurement are activated with the convenient blue OK button, while two menu buttons are used for navigation

Versatile and tough
The tried and tested electro-chemical Dräger sensor in the Alcotest 6000 is distinguished by its very fast response times and a long service life. It operates with extreme precision and reliability. The analysis is reliable even at temperatures of -5 to +50 °C / 23 to 122 °F. The sensor also delivers reliable results quickly in case of a high alcohol content, for both active and passive measurements.

Convenient to use
Dealing with intoxicated people requires a high degree of attention and concentration. An intuative operation of the device is an important aspect for ease of use and smooth breath testing procedures.
All measurement functions can be operated with just one button to make it easier for you to perform the test. The large back-lit display is easy to understand due to its full-text messages which guide you securely through the alcohol test. An LED and audible signal complement the display and indicate the end of a measurement process. Two menu buttons are used to navigate through the menu, enabling you to perform functions such as reviewing the last test results and optional printing.

Simply hygienic: the Slide'nçlick mouthpiece
The sophisticated product design meets the requirements for performing the breath alcohol test quickly, easily and hygienically: The shape of the Slide‘n‘click mouthpiece allows you to intuitively fit it correctly, even in the dark. The Alcotest 6000 is ready to use again immediately after changing the mouthpiece. Furthermore, attempts at obstruction are consistently rejected by the device: The air outlet cannot be closed, foiling any attempts to manipulate the device when giving a breath sample.
A spacer on the mouthpiece keeps the lips of the person being tested from coming into contact with the device’s housing. The spacer can also be used as a mouthpiece ejector if necessary. Mouthpieces with return valve are also available upon request.

The Alcotest Hygiene Plus
Hygiene is an increasingly important part of our everyday lives. Dräger Alcotest breath-alcohol detection devices use non-invasive measuring technologies with a high degree of hygiene – for the user as well as the test subject – thanks to the following features:

During testing, the exhaled air is directed past rather than through the device
There is a 90° angle between the user and the test subject during testing
Disposable mouthpiece is individually packaged
Benefits of the Slide ’n’ Click mouthpieces
safe, hygienic distance between user and test subject
spacer prevents direct contact between lips and device
mouthpiece is easy to remove
the non-return valve prevents inhalation of air through mouthpiece
Innovation born out of tradition
With over 65 years of experience, Dräger is the global market leader in the field of breath-alcohol testing. Police in many countries use devices from the Alcotest product series in everyday traffic monitoring. The Alcotest 6000 is made in Germany and meets the highest standards of quality. It uses the same, professional EC sensor technology, ensuring precise test performance and secure results.

  • Measuring principle: Electrochemical Dräger sensor for 1/4" technology, alcohol specific
  • Measuring range: 0 to 2.5 mg/L; if measurement range limit is exceeded, a message is displayed
  • Sampling: Standard: automatic sampling when minimum volume resp. defined blow time is reached; Passive sampling without mouthpiece or manual initiation of sampling possible
  • Ready for use: Approx. 2 s after switching on
  • Display of the measurement results: After approx. 3 s (at 0 mg/L, room temperature)
  • Operating temperature: -5 to +50 °C / 23 to 122 °F
  • Relative humidity: 10 to 100 % relative humidity (non-condensing and in operating state)
  • Ambient pressure: 600 to 1,300 hPa / 17.7 to 38.4 inch Hg
  • Display: Graphic backlit LCD display; 32 x 22 mm / 1.3" x 0.9" (128 x 64 pixels)
  • LED2-colour, to support display of results and warning messages
  • Audible signal: Different signal tones to support display messages and warnings
  • Datalogger: Storage of last 500 tests with test numbers
  • Power supply: 1 x CR123A-Battery, charge level indicator in display, with one battery approx. 1,500 breath tests can be done.
  • Mouthpiece adaption: Improved Slide’n’click mouthpiece attachment; can be fitted for right or left orientation
  • Mouthpiece: Hygienically, individually packaged, with tamper-proof, tamperproof air outlet, mouthpiece ejector and spacer between mouth and instrument housing
  • Operating concept: Measurement functions can be performed using just one button; menu navigation is via two menu button
  • Calibration: Wet gas or dry gas calibration
  • Housing: Impact resistant ABS/PC
  • Dimensions (W x H x D), weight: Approx. 50/60 x 141 x 31 mm / 2"/2.4" x 5.6" x 1.2"; approx. 150g / 0.33 lbs, incl. battery
  • Instrument configuration: Direct menu-guided configuration of instrument settings (PIN required) No additional PC software needed
  • Vibration and shock: EN 60068-2-27, EN 60068-2-6; EN600-2-64
  • CE marking: CE conform
  • Norms: EN 15964, NHTSA, FDA Conformity, depending on configuration
  • Internal clock: Warning or deactivation after end of service interval
  • Protection type: IP54
  • Bluetooth* (optional): For the communication with the Dräger Mobile Printer BT