nul

SSC accepte les retours et les remboursements uniquement pour les défauts de fabrication - Veuillez appeler notre centre de service pour plus de détails. 

Calibration and Bump Testing - X-dock 6300 | Dräger

(Pas encore de commentaires) Écrire un commentaire
SKU :
8321900
UPC :
4026056064199
  • Calibration and Bump Testing - X-dock 6300
  • Calibration and Bump Testing - X-dock 6300
  • Calibration and Bump Testing - X-dock 6300
$5,301.00
Souvent achetés ensemble :

Description

Calibration and Bump Testing - X-dock 6300 | Dräger

Dräger X-dock®
The Dräger X-dock series provides you with full control of your portable Dräger gas detection instruments. Automatic bump tests and calibrations with reduced test gas consumption and short testing times save time and money. Comprehensive documentation and evaluations provide you with a clear overview.

As versatile as your requirements
The X-dock is available in a wide variety of versions. The X-dock 5300 includes a master station including a module for a gas detection instrument from the X-am 1/2/5x00 or Pac family. It is immediately ready to use. The X-dock 6300 and 6600 versions can be configured freely. They consist of a master station and can be expanded with up to 10 modules for X-am 1/2/5x00 and/or Pac 1 gas detection instruments.

Easier than ever before
Insert the device, close the lid and remove it when the indicator goes "green" – a test with the X-dock is just that simple. It immediately detects all sensor combinations. Furthermore, the X-dock automatically tests and adjusts when all required test gases are connected. The station works independently and can be configured and used without a PC. The station is operated via an integrated touchscreen. A gas detection instrument is detected as soon as it is inserted, and all data is documented in the database.

More safety thanks to complete documentation
Do you need to document whether or not your devices are ready for operation? Who tested which device when, and what the result was? The X-dock stores all of the relevant data and reads the collected information from the gas detection instruments for subsequent evaluations – providing you with complete control every step of the way. You can use the reporting function (report wizard) to create customised reports. Furthermore, you can print a calibration certificate right at the stations, since the X- dock series supports standard PostScript-compatible USB printers. This functionality allows the user to manage all requirements of EN 60079-29-1 and EN 60079-29-2.

Automatically reduced costs
With a reduced gas flow (300 mL/min instead of 500 mL/min) per module, you save costs on test gases. Short testing times reduce the overall maintenance efforts. The valve concept (patent pending) requires one pump only, resulting in the need for less wear and tear parts. The valves automatically switch the test gases and – when connected – the compressed air as well.

Significant time savings
Up to 10 modules can be connected to the X-dock at any given time, allowing you to test gas detection instruments simultaneously but also independently of each other. The automatic bump test also saves time, because the test only takes 8 to 15 seconds 2. All Dräger test gas cylinders are already stored in the database – entering the part number will automatically fill in the fields required for the gas configuration. This eliminates the need for manual data entry.

Overview of results
The additional "X-dock Manager" software offers you even more comfort: It produces a detailed evaluation of the data in the calibration system and gas detection instruments, and presents the information in various graphics and statistics – providing you with a complete overview of all results. All connected X-dock systems can be connected in one network. Therefore, the data is not only stored locally in the system, but in a central database as well. With the X-dock manager you are always in control.

Further benefits
touchscreen operation at the master station
up to three configurable test routines
automatic leak tests
automatic tests of alarm elements (acoustic, visual and vibration alarms)
optional charging function for X-am 1/2/5x00
replaceable seal cartridge
12V operation (e.g. in vehicles) possible
can be subsequently expanded with up to 10 modules (X-dock 6300/6600)
evaluation of sensor response time
The X-dock manager offers much more
gas exposure in specific areas, number of conducted tests, device availability, overview of created and sent reports
templates for regular reports
an issue and return function to allocate gas detection instruments to specific individuals
monitoring of stations within the network: All connected systems can be monitored (e.g. information on the gas configuration)
overview of devices: direct access to test reports and device configuration
notifications, also via email, e.g. if test gases are running out
VLAN capable

  • Operating Temperature: -5°C to 45°C
  • Storage Temperature: -20°C to 50°C
  • Humidity: 100%, not condensing
  • Atmospheric Pressure: 600 to 1050 mbar
  • Dimensions: 109 x 61 x 206 mm
  • Weight: 0.45 kgs
  • Power supply: 4 x 1.5V alkaline (AA) batteries
  • Tout voirFermer