Benzene 0.15-10 ppm - Benzene gas microtube for low-level detection (0.15-10 ppm) with X-act 7000. Suitable for occupational health, refineries, and chemical storage monitoring.
Perchlorethylene 1-500 ppm - Perchlorethylene (PERC) microtube for detection in dry cleaning, industrial hygiene, and environmental testing (1-500 ppm) with X-act 7000.
Hydrogen Sulfide 0.1-50 ppm - Hydrogen sulfide microtube for low/medium range H2S detection (0.1-50 ppm) in sewers, oil & gas, and wastewater operations, via X-act 7000.
Nitrous fumes 0.25-50 ppm - Nitrous fumes (NOx) detection microtube for environmental, laboratory, or compliance monitoring (0.25-50 ppm), for use with X-act 7000.
Formaldehyde 0.15-3 ppm - Formaldehyde microtube for sensitive, rapid measurement (0.15-3 ppm) in labs, healthcare, and chemical production, with X-act 7000.
Sulfur dioxide 0.05-5 ppm - Sensitive SO2 microtube (0.05-5 ppm) for occupational health, power generation, and chemical plant monitoring via X-act 7000.
Carbon Dioxide 200-50000 ppm - High-range CO2 microtube (200?50000 ppm) for greenhouse, fermentation, or industrial gas analysis, with X-act 7000.
Ethylene Oxide 25-250 ppb - Ultra-low range ethylene oxide microtube (25-250 ppb) for sterilization monitoring and process control. Use with X-act 7000.
Hydrogen sulfide 100-2000 ppm - High-range hydrogen sulfide microtube (100?2000 ppm) for process industry, oil/gas, and emergency situations, with X-act 7000.
Vinyl chloride 0.1-10 ppm - Vinyl chloride detection microtube (0.1?10 ppm) for compliance air monitoring in plastics and polymer facilities, with X-act 7000.
Toluene 10-1000 ppm - Microtube for toluene vapor monitoring (10?1000 ppm), supports workplace air testing in paint shops, labs, and industry; use with X-act 7000.
Xylene 10-1000 ppm - Microtube for xylene exposure monitoring (10?1000 ppm) in laboratory, industrial painting, and chemical storage areas. Use with X-act 7000.
Petroleum Hydrocarbons 10-3000 ppm - Broad-range microtube for petroleum hydrocarbons (10?3000 ppm) for use in tank cleaning, spill response, and oil refineries with X-act 7000.
Demo - Demonstration microtube for training, device check, and customer education with X-act 7000.
Trichlorethylene 0.25-50 ppm - Trichlorethylene (TCE) detection microtube (0.25?50 ppm), for degreasing, solvent, and environmental testing, with X-act 7000.
Phosgene 10-1000 ppb - Phosgene detection microtube (10?1000 ppb) for emergency response, chemical safety, and industrial hygiene using X-act 7000.
Mercaptan 50-6000 ppb - Mercaptan (odorant) microtube (50?6000 ppb) for natural gas leak detection and odor control. Use with X-act 7000.
Ozone 10-1000 ppb - Ozone microtube (10?1000 ppb) for air quality and sterilization monitoring. Use with X-act 7000.
1,3-Butadiene 25-500 ppb - Ultra-low detection of 1,3-Butadiene (25?500 ppb) for worker safety in rubber and plastics industry; X-act 7000 compatible.
Methylene Chloride 10-500 ppm - Methylene chloride microtube (10?500 ppm) for solvent, industrial, or environmental exposure, used with X-act 7000.
Hydrocyanic acid 0,5-50 ppm - Hydrocyanic acid (HCN) microtube (0.5?50 ppm) for emergency response, chemical plant, or research, with X-act 7000.
MTBE 2-200 ppm - MTBE microtube (2?200 ppm) for monitoring gasoline additive exposure in refineries and air quality, with X-act 7000.
Formaldehyde 5-150 ppb - Ultra-low formaldehyde microtube (5?150 ppb) for sensitive air, lab, and hospital monitoring, compatible with X-act 7000.
Ethylene Oxide 0.25-10 ppm - Mid-level ethylene oxide detection microtube (0.25?10 ppm) for sterilization validation and regulatory compliance. For X-act 7000.
Benzene 1-150 ppb - Ultra-sensitive benzene microtube (1?150 ppb) for environmental, urban air, and health risk assessments with X-act 7000.