null

Welcome to Safety Supplies Canada!

Warehouse Locations: Vancouver, BC | Edmonton, AB | Winnipeg, MB | Toronto, ON | Laval, QC | Halifax, NS

Safety Supplies Canada
Dräger

Draeger Detector Tube

Price $99.75
(No reviews yet) Write a Review
SKU:
DraegerDetectorTube
Condition:
New
Adding to cart… The item has been added

Product description

Draeger Detector Tube | Dräger

Dräger Short-term Tubes
Tried and tested a million times: Worldwide, the Dräger Short-term Tubes have proven to be a very cost-effective and reliable method for the measurement of gases. Decreasing occupational exposure values, special customer requirements and new legal regulations made it necessary to develop even more sensitive Dräger-Tubes.

Quick and targeted measurements
For spot measurement more than 500 different gases can be detected. The measurement usually takes between 5 seconds and 15 minutes. Furthermore, the easy-to-use Dräger-Tubes have already been calibrated and form a complementary unit with the Dräger-Tube pumps.

Easy handling
The Short-term Tubes are used either manually with the Dräger-Tube pump accuro or automatically with the Dräger X-act 5000. The results can then be read directly at the end of the measurement process.

Fields of application
air examinations at the workplace in the range of legal limit values
technical gas analysis in the areas of emission concentrations / immission concentrations
measurements of compressed air / compressed gases

Flexible use
A large number of different gases and vapors can be measured by the Short-term Tubes. These tubes are used e.g. for the determination of concentration peaks, the measurement of exposures in the inhalation area, the determination of possible leakages as well as for the analysis of air in sewers, shafts, tanks or other confined spaces.

Available Options

  • Triethylamine 5/a (10) - Dräger Tube Triethylamine 5/a (10). Detector tubes for measuring triethylamine vapors. 10 tubes per box.
  • Benzene 5/a (10) - Draeger Tube Benzene 5/a (10) detector tubes for measurement of benzene vapor in workplace air. Pack of 10.
  • Chloroprene 5/a (10) - Dräger Tube Chloroprene 5/a (10). For quantitative measurement of chloroprene concentrations.
  • Hydrogen Sulfide 1/c (10) - Dräger Tube Hydrogen Sulfide 1/c (10). Colorimetric tubes for low range H2S detection in air.
  • Nitrogen Dioxide 2/c (10) - Dräger Tube Nitrogen Dioxide 2/c (10). For determining nitrogen dioxide concentrations.
  • Acetic Acid 5/a (10) - Dräger Tube Acetic Acid 5/a (10). Measures airborne acetic acid with colorimetric precision.
  • Formic Acid 1/a (10) - Dräger Tube Formic Acid 1/a (10). Fast-response tubes for measuring formic acid exposure.
  • Styrene 10/a (10) - Dräger Tube Styrene 10/a (10). Rapid detection of styrene concentrations in workplace air.
  • Toluylen Diisocyanat 0.02/a (9) - Dräger Tube Toluylen Diisocyanat 0.02/a (9). For accurate measurement of toluene diisocyanate.
  • Ethyl glycol acetate 50/b (10) - Dräger Tube Ethyl glycol acetate 50/b (10). Measures airborne ethyl glycol acetate exposure.
  • Sulfur Dioxide 0.1/a (10) - Dräger Tube Sulfur Dioxide 0.1/a (10). For low-range SO2 gas measurement.
  • Ethylene 50/a (10) - Dräger Tube Ethylene 50/a (10). Measurement of ethylene gas in ambient air.
  • Benzene 5/b (10) - Dräger Tube Benzene 5/b (10). Secondary range benzene measurement tube.
  • Epichlorohydrin 5/c (10) - Dräger Tube Epichlorohydrin 5/c (10). For monitoring epichlorohydrin in industrial settings.
  • Methylacrylate 5/a (10) - Dräger Tube Methylacrylate 5/a (10). Detection tube for methylacrylate vapor.
  • Hydrochloric Acid 50/a (10) - Dräger Tube Hydrochloric Acid 50/a (10). Colorimetric tube for HCl detection.
  • Ethylene Oxide 25/a (10) - Dräger Tube Ethylene Oxide 25/a (10). For detection of ethylene oxide gas in air.
  • Nitric Acid 1/a (10) - Dräger Tube Nitric Acid 1/a (10). Measures airborne nitric acid concentrations.
  • Oil 10/a-P (10) - Dräger Tube Oil 10/a-P (10). Detection tube for oil mist measurement.
  • Dimethyl sulfide 1/a (5) - Dräger Tube Dimethyl sulfide 1/a (5). For measuring dimethyl sulfide in air.
  • Phosphoric Acid Esters 0.05/a (10) - Dräger Tube Phosphoric Acid Esters 0.05/a (10). Sensitive to organophosphates and related esters.
  • Sulfur Dioxide 0.5/a (10) - Dräger Tube Sulfur Dioxide 0.5/a (10). Mid-range SO2 gas measurement tube.
  • Water Vapour 5/a-P (10) - Dräger Tube Water Vapour 5/a-P (10). Rapid indication of water vapor presence in air.
  • Chlorobenzene 5/a - Dräger Tube Chlorobenzene 5/a. For measurement of chlorobenzene vapor levels.
  • Sulfuric acid 1/a (9) - Dräger Tube Sulfuric acid 1/a (9). Monitors sulfuric acid aerosols in workplace.
  • Cyanide 2/a (10) - Dräger Tube Cyanide 2/a (10). For monitoring airborne cyanide exposure.
  • Hydrogen Sulfide 2/a (10) - Dräger Tube Hydrogen Sulfide 2/a (10). Higher concentration H2S measurement in workplace settings.
  • Chloroform 2/a (5) - Dräger Tube Chloroform 2/a (5). For measurement of chloroform in ambient air.
  • Ethylene Oxide 1/a (5) - Dräger Tube Ethylene Oxide 1/a (5). For monitoring ethylene oxide concentrations.
  • Mercaptan 0.5/a (10) - Dräger Tube Mercaptan 0.5/a (10). Measures airborne mercaptan for odor detection and safety.
  • Petrol Hydrocarbons 100/a (10) - Dräger Tube Petrol Hydrocarbons 100/a (10). For petroleum hydrocarbon vapor quantification.
  • Oil Mist 1/a (10) - Dräger Tube Oil Mist 1/a (10). Detects airborne oil mist in industrial environments.
  • Formaldehyde 0.2/a (10) - Dräger Tube Formaldehyde 0.2/a (10). Sensitive tube for formaldehyde detection.
  • Styrene 10/b (10) - Dräger Tube Styrene 10/b (10). For secondary range styrene measurement.
  • Xylene 10/a (10) - Dräger Tube Xylene 10/a (10). Measures airborne xylene in workplace environments.
  • Aniline 0.5/a (10) - Dräger Tube Aniline 0.5/a (10). For detecting aniline vapors.
  • Ozone 0,05/b (10) - Dräger Tube Ozone 0.05/b (10). Sensitive tube for ozone monitoring.
  • Ammonia 2/a (10) - Dräger Tube Ammonia 2/a (10). For routine ammonia monitoring in air.
  • Carbon Tetrachloride 1/a (10) - Tube for measuring carbon tetrachloride concentration in air.
  • Hydrogen Peroxide 0.1/a (10) - Tube for detecting hydrogen peroxide vapors in workplace air.
  • Amine Test (10) - Tube for detecting amine compounds in ambient air.
  • Acid Test (10) - Tube for detecting acid vapors in air.
  • activat.f. Formaldehyde 0.2/a (10) - Activator tube for sensitive detection of formaldehyde in air.
  • Hydrogen Sulfide 2%/a (10) - Tube for high concentration hydrogen sulfide measurement in air.
  • Benzene 2/a (5) - Tube for detecting benzene vapors in air for workplace safety.
  • Ammonia 20/a-D (10) - Tube for high-range ammonia detection in workplace air.
  • Water Vapour 0.1/a (10) - Tube for humidity and moisture measurement in air.
  • Ethylene Glycol 10 (5) - Tube for detecting ethylene glycol vapor in workplace air.
  • Hydrogen Sulfide 0.2/a (10) - Tube for low concentration H2S detection in workplace air.
  • Perchloroethylene 2/a (10) - Tube for detecting perchloroethylene vapor in air.
  • Hydrogen 0.2%/a (10) - Tube for hydrogen concentration measurement in workplace air.
  • Phosgene 0.02/a (10) - Tube for low-level phosgene detection in air.
  • Sulfur Dioxide 50/b (10) - Tube for high concentration sulfur dioxide measurement in workplace air.
  • Halogenated Hydrocarbons 100/a (8) - Tube for detecting halogenated hydrocarbons in workplace air.
  • Phosphine 0.01/a (10) - Tube for ultra low-level phosphine detection in air.
  • Phosphine 25/a (10) - Tube for high concentration phosphine detection in workplace air.
  • Phenol 1/b (10) - Tube for on-site detection of phenol vapors in workplace air.
  • Toluene 5/b (10) - Tube for toluene vapor detection in occupational air.
  • Hydrochloric/Nitric Acid 1/a (10) - Tube for detecting hydrochloric and nitric acid vapors in workplace air.
  • Petroleum Hydrocarbons 10/a (10) - Tube for petroleum hydrocarbons vapor detection in air.
  • Toluene 50/a (10) - Tube for high concentration toluene detection in workplace air.
  • Ammonia 0.25/a (10) - Tube for low-level ammonia detection in air.
  • Vinyl Chloride 0.5/b (10) - Tube for vinyl chloride vapor detection in process and environmental monitoring.
  • Toluene 100/a (10) - Tube for detecting very high concentrations of toluene in workplace air.
  • Benzene 15/a (10) - High-range benzene detector tube for air quality monitoring.
  • Formaldehyde 2/a (10) - High-range formaldehyde detector tube for workplace monitoring.
  • Water Vapour 1/b (10) - Tube for high-range water vapor (humidity) measurement in air.
  • Phosphine 1/a (10) - Field detection tube for phosphine vapor in air.
  • Mercaptan 20/a (10) - High concentration mercaptan detector tube for gas distribution safety.
  • Trichloroethylene 50/a (10) - Tube for trichloroethylene vapor detection in workplace air.
  • Carbon Disulfide 3/a (10) - Tube for detecting carbon disulfide vapor in workplace air.
  • Ammonia 5/b (10) - Tube for mid-range ammonia detection in industrial hygiene settings.
  • Hydrogen Flouride 0.5/a (10) - Tube for low-level hydrogen fluoride vapor detection in air.
  • Mercaptan 0.1/a (10) - Tube for trace mercaptan odorant detection in air for leak detection.
  • Acetone 40/a (5) - Tube for acetone vapor detection in workplace air (solvent monitoring).
  • Chloropikrine 0.1/a (10) - Tube for low-level chloropikrine vapor detection in air.
  • Diesel fuel (10) - Tube for detecting diesel fuel vapors in workplace air.
  • Chlorine Dioxide 0,025/a (10) - Tube for ultra-low ClO2 vapor measurement in chemical environments.
  • Carbon Tetrachloride 0,1/a (10) - Tube for low-concentration carbon tetrachloride vapor detection.
  • Iodine 0.1/a (10) - Tube for trace iodine vapor detection in laboratory and environmental air.
  • PID Prefilter Humidity - Prefilter tube to reduce humidity interference in PID VOC measurements.
  • Hydrocarbons 0.1%/c (10) - Tube for trace hydrocarbons/VOC detection in environmental/industrial air.
  • Hydrocarbons 2/a (10) - Tube for mid-range hydrocarbon vapor detection in workplace air.
  • Methylene Chloride 20/a (10) - Tube for methylene chloride vapor detection in air (solvent safety).
  • Hydrogen Cyanide 0.5/a (10) - Tube for low-level hydrogen cyanide detection in chemical/environmental air.
  • Nitrogen Dioxide 0.1/a (10) - Tube for ultra-low concentration nitrogen dioxide measurement in air.
  • Hexane 10/a (10) - Tube for hexane vapor detection in occupational air and process environments.
  • Phosphine 0.1/c (10) - Tube for ultra-low phosphine vapor measurement in workplace/process air.
  • Cyanogen Chloride 0,25/a (10) - Detection tube for cyanogen chloride (0.25/a, 10 tubes) for emergency response, chemical plants, and military applications.
  • Natural Gas Test (5) - Detector tube set (5 pcs) for fast qualitative natural gas detection in pipelines, industrial sites, and emergency leak checks.
  • Ethyl Acetate 200/a (10) - Detector tubes for ethyl acetate vapor (200/a, 10 tubes), supporting industrial hygiene, printing, and coatings quality control.
  • Carbon Dioxide 5%/a (10) - CO2 detector tube (5%/a, 10 tubes) for monitoring process environments, fermentation, and confined space safety.
  • Chlorine 50/a (10) - Colorimetric gas detector tubes for chlorine gas (Cl2) at 50 ppm range. Used for water treatment plants, chemical processing, and environmental air monitoring.
  • Ozone 10/a (10) - Gas detector tubes for ozone (O3) detection at 10 ppm. Ideal for laboratory, cleanroom, and ozone disinfection system monitoring.
  • Trichloroethane 50/D (5) - Detector tubes for trichloroethane vapor (50 ppm). Used in industrial degreasing, solvent handling, and safety compliance.
  • Phosphine 50/a (10) - Rapid colorimetric tubes for phosphine (PH3) measurement up to 50 ppm, essential in fumigation, grain storage, and emergency response.
  • Acetone 100/b (10) - Detector tubes for acetone vapor (100 ppm), for workplace exposure checks in painting, printing, or solvent-using industries.
  • Mercury Vapor 0.1/b (10) - Highly sensitive detector tubes for mercury vapor (0.1 mg/m³), for laboratory safety, hazardous waste, and environmental monitoring.
  • carbon Pre-Tube (10) - Pre-tubes for carbon compound filtering in complex gas mixtures, used as accessories for specific Draeger tube applications.
  • Sulphur Dioxide 20/a (10) - Sulphur dioxide (SO2) detector tubes (20 ppm), used for emissions, refineries, and process gas checks.
  • Chlorine 0.2/a (10) - Ultra-low level chlorine (Cl2) detector tubes (0.2 ppm), for hazardous material, water plant, or disinfection system checks.
  • Arsine 0,05/a (10) - Arsine (AsH3) detector tubes (0.05 ppm) for semiconductor, metallurgy, and chemical safety audits.
  • Carbon Dioxide 1%/a (10) - High-range CO2 detector tubes (1% vol), suitable for process gas, fermentation, and brewery environments.
  • Organic Arsenic Cpds & Arsine (10) - Detector tubes for organic arsenic compounds and arsine, used in semiconductor, lab, and hazardous material applications.
  • Styrene 50/a (10) - Styrene gas detector tubes (50 ppm), for plastics, rubber, and fiberglass manufacturing site monitoring.
  • Hydrogen Sulfide 0,2%/A (10) - Hydrogen sulfide (H2S) detector tubes (0.2%), for oil and gas, wastewater, and confined space entry.
  • H2S + SO2 0.2%/A (10) - Combined H2S and SO2 gas tubes (0.2%) for simultaneous detection in process and emergency settings.
  • Phosgene 0.25/c (10) - Phosgene gas detector tubes (0.25 ppm), vital for chemical industry, emergency response, and compliance audits.
  • Polytest (10) - Polytest multi-gas detector tubes for screening multiple gas hazards in workplace and environmental safety audits.
  • Carbon Monoxide 0,3%/b (10) - Detector tubes for carbon monoxide (CO) at 0.3% for hazardous leak and process monitoring, suitable for industrial and confined space checks.
  • Hydrogen Flouride 1.5/b (10) - Hydrogen fluoride (HF) detector tubes (1.5 ppm) for chemical, etching, and glass industries, supporting health and compliance.
  • Nitrous Fumes 2/a (10) - Nitrous fumes (NOx) detector tubes (2 ppm) for emission monitoring in industrial and laboratory environments.
  • Sulfur Dioxide 1/a (10) - Sulfur dioxide (SO2) detector tubes (1 ppm) for stack emission, refinery, and power plant monitoring.
  • Hydrazine 0.25/a (10) - Hydrazine detector tubes (0.25 ppm) for aerospace, chemical, and laboratory safety applications.
  • Ammonia 0.5%/a (10) - Ammonia detector tubes (0.5% vol) for fertilizer, refrigeration, and chemical plants monitoring.

Related Products